top of page

The consistently developed and enhanced STAUFF Hydraulic Accessories product range contains of well thought-out and sophisticated components suited to meet or exceed the increasing requirements of designing and building tanks, reservoirs, power packs and gear boxes for industrial and mobile hydraulic applications.

Whether you require visual or visual/electrical fluid level and temperature indicators, tank filler breathers in a variety of designs made of plastic or metal, or desiccant air breathers to protect your reservoir from contamination and moisture: STAUFF Hydraulic Accessories will provide you with the product you need.


The programme is completed by suction strainers and Diffusers that are positioned within the reservoir and connected directly to the suction and return lines.

For challenging applications, STAUFF is able to provide technically modified product versions, which, for example, convince with their outstanding resistance to external influences (such as high or low temperatures, aggressive media or UV exposure) or their compact and light-weight design.


STAUFF guarantees prompt service, even for customised solutions according to customer’s  specifications or based on our in-house development.

See Products in Detail
Fluid Level and Temperature Indicators
düğme01.jpg
01.jpg
Level Gauge Type SNA

Visual fluid level indication in hydraulic reservoirs with maximum tank pressures not exceeding 2 bar / 29 PSI

02.jpg
Level Gauge (Special Options) Type SNA/SNK

Visual fluid level indication in hydraulic reservoirs with maximum tank pressures not exceeding 2 bar / 29 PSI; ideal for custom applications in terms of reservoir capacities and dimensions

03.jpg
Level Gauge Type SNK

Visual / electrical fluid level indication in hydraulic reservoirs with maximum tank pressures not exceeding 2 bar / 29 PSI

04.jpg
Level Gauge (Compact Design) Type SNKK

Visual / electrical fluid level indication in hydraulic reservoirs with maximum tank pressures not exceeding 2 bar / 29 PSI; ideal for applications in which space is limited

05.jpg
Thermo Switch Type TS

Fluid temperature measurement in conjunction with STAUFF Level Gauges SNA, SNK and SNKK

06.jpg
Dial Thermometer with Probe Types T1/T2

Visual fluid temperature measurement in conjunction with STAUFF Level Gauges SNA, SNK and SNKK

07.jpg
Temperature Sensor Type TS-SNA/SNK-PT100

Fluid temperature measurement in conjunction with STAUFF Level Gauges SNA, SNK and SNKK; Analysis of signals with required equipment, simply connect to your on board control unit or PLC.

08.jpg
Temperature Sensor with Direct Installation Set Type TS-SNA/SNK-PT100-T

Direct fluid temperature measurement without STAUFF Level Gauges SNA, SNK and SNKK; Analysis of signals with required equipment, simply connect to your on board control unit or PLC.

09.jpg
Anti-Drain Valve Type SDV-SNA/SNK

Anti-drain valve to be used in conjunction with banjo bolts of level gauges, allowing these to be removed and replaced quickly and easily without spillage of fluid from the hydraulic reservoir

10.jpg
Deutsch Adaptor Cable Type DT04-4P

Deutsch adaptor to use for adaption from M12 to Deutsch Plug DT04-4P.

11.jpg
Level-Temperature Switch Type SLTS

Level contact positions (L, H) are set as given in the order code. They can be adjusted individually later on.
Please consider a minimum distance of 40 mm / 1.57 in between the switching points.

Characteristics

The STAUFF Level-Temperature Switches (SLTS Series) are unique in their design and modularity. One of the greatest advantages is the ability of the end-user to adjust the switching level. The internal support wire carrying the level and temperature switches makes it a simple and quick job to change the level switch position.

  • Suitable for Mineral Oil and HFC fluids,other fluids on request

  • Either 1 or 2 level contacts available

  • 1 integrated temperature switch (optional)

  • Standard electrical function:

Level contacts: Normally closed, opens with falling level

Temperature contacts: Normally closed, opens with rising temperature

Fluid Level and Temperature Indicators
Tank Filler Breathers
düğme02.jpg
12.jpg
Plastic Filler Breather Types SPB-1 / 2 / 3 (Threaded Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

13.jpg
Plastic Filler Breather Types SPB-4 / 5 (Flange Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

14.jpg
Plastic Dipstick Types DS-1 / 2 / 3 Anti-Splash Feature

Special designs and alternative materials available on request. Please contact STAUFF for further details.

18.jpg
Plastic Filler Breather Type SPBN
(Compact Design; Threaded or Bayonet Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments; ideal for applications in which space is limited

Height above tank – 15 mm / – .59 in in comparison with SPB-2

19.jpg
Mounting Set for Baskets (including Bayonet Flange, Gaskets and Bolts)
  • 6 slotted pan head screws made of steel, zinc-plated (ISO 1580 M5 x 12-5.8)

  • Bayonet flange made of steel, zinc-plated, with six-hole bolt pattern acc. to DIN 24557, part 2

  • 2 gaskets made of NBR (Buna-N®) - one for underneath and one for on top of the basket

20.jpg
Plastic Filler Breather Mini Type SPBM (Threaded Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

21.jpg
Plastic Filler Breather Type SES
(Threaded or Welded Versions)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

22.jpg
Metal Filler Breather Type SMBT-47
(Threaded Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

23.jpg
Metal Filler Breather Type SMBB-47
(Bayonet Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

24.jpg
Metal Filler Breather Type SMBT-80
(Threaded Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

25.jpg
Metal Filler Breather Type SMBB-80
(Bayonet Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

26.jpg
Metal Breather Type SMBP-80
(Push-On Version)

Designed to be used as filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

27.jpg
Lockable Metal Filler Breather Type SMBL (Clamping, Threaded and Push-On Version)

Designed to be used as lockable filler ports for hydraulic reservoirs, allowing the reservoir to breathe whilst protecting it from contamination found in harsh environments

28.jpg
Side Mount Bracket Type ASMB-1
(Polyamide Version)

Lateral fastening of filler breathers with a six-hole flange connection similar to DIN 24557, part 2 to vertical or sloped walls of hydraulic reservoirs; ideal for applications in which space is limited

29.jpg
Side Mount Bracket Type ASMB-2
(Aluminium Version)

Lateral fastening of filler breathers with a six-hole flange connection similar to DIN 24557, part 2 to vertical or sloped walls of hydraulic reservoirs; ideal for applications in which space is limited

30.jpg
Extended Bayonet Flange Type EBF

Designed to raise filler breathers either 24 mm / .94 in or 54 mm / 2.12 in above the actual mounting surface of the reservoir to prevent contamination from blocking the filter element

31.jpg
Weld Riser Type WR

Designed to raise filler breathers 25,4 mm / 1.00 in above the actual mounting surface of the reservoir to prevent contamination from blocking the filter element whilst eliminating the requirement to drill and tap on the reservoir

Tank Filler Breathers
Giant and Desiccant Air Breathers
düğme03.jpg
32.jpg
Giant Air Breather Type SGB

Originally designed to be used as replaceable air filter elements for STAUFF Desiccant Breathers, they can also be used as seperate air filters for hydraulic reservoirs

33.jpg
Breather Adaptor Type TBA

Converts from female threaded Giant Air Breather or Spin-On Filter Element to a male thread, and thus allows for direct installation on top of hydraulic reservoirs

34.jpg
Pressurised Breather Adaptor Type TBA-075-B12F-B12F-B0.35

Increasing the service life and reducing maintenance intervals of tank filler breathers and desiccant breathers due to less breathing

35.jpg
Desiccant Air Breather incl. Air Filter Element Type SDB

Combination of air breather and water removal filter

36.jpg
Desiccant Air Breather (Disposable Version) Type SVDB

Combination of air breather and water removal filter

37.jpg
Desiccant Air Breather with Check Valves Type SDB-CV

Combination of air breather and water removal filter with integrated check valves to increase the lifetime of the desiccant material; particularly suited for gearbox applications

38.jpg
Adaptor Plate Type AP

Designed to simplify the installation of Desiccant Air Breathers and enable the use of a visual contamination indicator

39.jpg
Visual Contamination Indicator
Type FM

Designed to indicate the status of air filter elements

40.jpg
Oil Demister Type TBA-OD

Designed to prevent oil mist from leaving the hydraulic reservoir through air breathers

Giant and Desiccant Air Breathers
Suction Strainers
düğme04.jpg
41.jpg
Suction Strainer (Polyamide End Cap) Type SUS

Designed as in-tank suction strainer elements for direct installation into suction lines of pumps; should always be installed below the minimum fluid level of the reservoir

42.jpg
Suction Strainer (Aluminium End Cap) Type SUS

Designed as in-tank suction strainer elements for direct installation into suction lines of pumps; should always be installed below the minimum fluid level of the reservoir

Features
  • Available with female NPT thread (ANSI B1.20.1)

  • Operating temperature range: -20 °C ... +100 °C / -4 °F ... +212 °F

Materials
  • Threaded end cap made of Aluminium; see page 50 for version with Polyamide (PA) end cap

  • Lower end cap and support tube made of Steel, zinc-plated

  • Filter material made of Stainless Steel Mesh (125 μm); alternative micron ratings of 60 μm and 250 μm on request

Suction Strainers
Diffusers
düğme05.jpg
43.jpg
Diffuser Type SRV
(Female BSP Threaded Version)

Designed for direct installation into return lines to reduce fluid aeration, foaming and noise; should always be installed below the minimum fluid leve

44.jpg
Diffuser Type SRV
(Female NPT Threaded Version)

Designed for direct installation into return lines to reduce fluid aeration, foaming and noise; should always be installed below the minimum fluid level

Features
  • Available with female NPT thread (ANSI B1.20.1)

  • Operating temperature range: -20 °C ... +100 °C / -4 °F ... +212 °F

  • Max. working pressure: 20 bar / 290 PSI

Media Compatibility
  • Suitable for use with Mineral and Petroleum based hydraulic fluids (HL and HLP)

Construction and Materials
  • 2 concentric tubes with inner spaced holes

  • Threaded end cap made of Aluminium

  • Other components made of Steel, zinc-plated

Diffusers
bottom of page